Product Details
1. General Introduction
EJA118E Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and pressure. It's diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly, connected to the transmitter using capillaries filled with fill fluid, available for fluid with temperature -50 to 310°C.
2. Measuring Span & Range limits
Measurement Span/Range |
kPa |
inH2O
(/D1)
|
mbar
(/D3)
|
mmH2O
(/D4)
|
M
|
Span |
2.5 to 100 |
10 to 400 |
25 to 1000 |
250 to
10000
|
|
Range |
-100 to
100
|
-400 to
400
|
-1000 to
1000
|
-10000 to
10000
|
H
|
Span |
25 to 500 |
100 to
2000
|
250 to
5000
|
0.25 to 5
kgf/cm2
|
|
Range |
-500 to
500
|
-2000 to
2000
|
-5000 to
5000
|
-5 to 5
kgf/cm2
|
3. Process temperature, Ambient temperature, and Working pressure
Liquid Fill |
Code |
Process temperature* |
Ambient temperature* |
Working pressure |
Silicone oil
(general use)
|
A |
–10 to 250°C
(14 to 482°F)
|
–10 to 60°C
(14 to 140°F)
|
2.7 kPa abs
(0.38 psi abs)
to flange rating pressure
|
Silicone oil
(general use)
|
B |
–30 to 180°C
(–22 to 356°F)
|
–15 to 60°C
(5 to 140°F)
|
Silicone oil
(high temperature use)
|
C |
10 to 310°C
(50 to 590°F)
|
10 to 60°C
(50 to 140°F)
|
Fluorinated oil
(oil-prohibited use)
|
D |
–20 to 120°C
(–4 to 248°F)
|
–10 to 60°C
(14 to 140°F)
|
51 kPa abs
(7.4 psi abs)
to flange rating pressure
|
Ethylene glycol
(low temperature use)
|
E |
–50 to 100°C
(–58 to 212°F)
|
–40 to 60°C
(–40 to 140°F)
|
100 kPa abs
(atmospheric pressure)
to flange pressure rating
|
Silicone oil
(high temp. and high
vacuum use)
|
1 |
–10 to 250°C
(14 to 482°F)
|
–10 to 60°C *
(14 to 140°F)
|
0.013 kPa abs
(0.0019 psi abs)
to flange rating pressure
|
Silicone oil
(high temp. and high
vacuum use)
|
2 |
10 to 310°C
(50 to 590°F)
|
10 to 60°C
(50 to 140°F)
|
Silicone oil
(high vacuum use)
|
4 |
–10 to 100 |